PR-4104
Universal uni-/bipolar signal transmitter
Measures and outputs uni-/bipolar voltage and current signals
Works with both passive and active inputs and outputs
Uses the PR 4500 display series for programming and process monitoring
Fast < 20 ms response time and excellent < 0.05% accuracy
Universally powered by 21.6…253 VAC / 19.2…300 VDC -

PR-4114
Universal Transmitter
Input for RTD, TC, Ohm, potentiometer, mA and V
2-wire supply > 16 V
FM-approved for installation in Div. 2
Output for current and voltage
Universal AC or DC supply -

PR-4116
Universal Transmitter
Input for RTD, TC, Ohm, potentiometer, mA and V
2-wire supply > 16 V
FM-approved for installation in Div. 2
Output for current, voltage and 2 relays
Universal AC or DC supply -

PR-9106B
IECEx – HART transparent repeater
24 VDC supply via power rail or connectors
Active and passive mA input
Active or passive output via the same two terminals
Splitter function – 1 in and 2 out
SIL3 Full Assessment and certified acc. to IEC 61508 -

PR-4131
Universal trip amplifier
Input for RTD, TC, Ohm, potentiometer, mA and V
2 adjustable alarm limits
FM-approved for installation in Div. 2
2 relay outputs
Universal AC or DC supply -

PR-4179
Universal AC / DC transmitter
Measures AC current and voltage signals
Outputs passive or active current signals
Programming, process monitoring and diagnostics via PR 4500
Response time < 0.75 s and excellent accuracy better than 0.3%
Universally powered by 21.6…253 VAC / 19.2…300 VDC -

PR-4510
Display / programming front
Programming display for all past and present 4000 / 9000 series devices, 3000 series devices where applicable, and all versions of ConfigMate 4590
Monitor process value and status from the built-in display
Scrolling help text in 7 languages -

PR-4511
Communication enabler
Programming display for all past and present 4000 / 9000 series devices, 3000 series devices where applicable, and all versions of ConfigMate 4590
Monitor process value and status from the built-in display
Scrolling help text in 7 languages -

PR-4512
Bluetooth communication enabler
Bluetooth communication between the PR 4000 and 9000 devices and iOS/Android devices
Live monitoring of process values and diagnostics on compatible smart devices or directly on the PR 4512
Advanced data logging and event logging using the built-in real-time clock -

PR-4184
Universal uni-/bipolar signal transmitter
Measures DC inputs up to ±300 V / ±100 mA with spans as low as 25 mV / 0.5 mA
Passive/active current output and buffered voltage output
Fast < 20 ms response time and excellent 0.05% accuracy
Universally powered by 21.6…253 VAC / 19.2…300 VDC -

PR-4222
Universal I/f converter
Input for RTD, TC, Ohm, potentiometer, mA and V
Frequency output NPN, PNP and TTL
Generates frequencies from 0…25000 Hz
2-wire supply > 16 V
Universal AC or DC supply -

PR-4225A
Universal f/I-f/f converter
Front programmable
Input: NAMUR, NPN, PNP, Tacho, TTL , S0 & switches
Output: Programmable bipolar mA / V, frequency or relay
Universal power supply 21.6…253 VAC / 19.2…300 VDC -

PR-3101
TC Converter
Type K & J Thermocouple converter.
High accuracy, better than 0.1% of span
Slimline housing of 6.1 mm
Excellent EMC performance and 50/60 Hz noise suppression
Selectable < 30 ms / 300 ms response time
Pre-calibrated temperature ranges selectable via DIP-switches -

PR-3102
PT100 Converter
2, 3 & 4 Wire PT100 Converter.
High accuracy, better than 0.1% of span
Slimline housing of 6.1 mm
Excellent EMC performance and 50/60 Hz noise suppression
Selectable < 30 ms / 300 ms response time
Pre-calibrated temperature ranges are selectable via DIP-switches -

PR-3111
TC Converter – Insolated
Type K & J Isolated Thermocouple converter.
Excellent accuracy, better than 0.05% of span
Slimline housing of 6.1 mm
Excellent EMC performance and 50/60 Hz noise suppression
Selectable < 30 ms / 300 ms response time
Pre-calibrated temperature ranges are selectable via DIP-switches -

PR-3112
PT100 Converter – Isolated
2, 3 & 4 Wire PT100 Converter.
Excellent accuracy, better than 0.05% of span
Slimline housing of 6.1 mm
Excellent EMC performance and 50/60 Hz noise suppression
Selectable < 30 ms / 300 ms response time
Pre-calibrated temperature ranges selectable via DIP-switches -

PR-3113
HART 7 temperature converter – isolated
Pt100, TC J and K Isolated temperature Coverter with HART signal output.
High accuracy, better than 0.05% of span
Slimline housing of 6.1 mm
Excellent EMC performance
Selectable 60 ms / 60 s response time
Pre-calibrated temperature ranges selectable via DIP-switches -

PR-3333
Pt100 converter, loop-powered
2-, 3- or 4-wire Pt100 temperature converter.
High accuracy, better than 0.1% of span
Slimline housing of 6.1 mm
Excellent EMC performance and 50/60 Hz noise suppression
Selectable < 30 ms / 300 ms response time
Pre-calibrated temperature ranges selectable via DIP-switches -

PR-3337
HART 7 temperature converter, loop-powered
Loop Powered / Pt100, TC J and K temperature converter with Hart Signal output.
High accuracy, better than 0.05% of span
Slimline housing of 6.1 mm
Excellent EMC performance
Selectable 60 ms / 60 s response time
Pre-calibrated temperature ranges selectable via DIP-switches -

PR-6331A
Universal 2-wire programmable transmitter
Loop Powered 2 Wire progtammable transmitter,
RTD, TC, Ohm, or mV input
Extremely high measurement accuracy
Galvanic isolation
Programmable sensor error value
1- or 2-channel version -

PR-6333A
RTD or Ohm 2-wire programmable transmitter
Loop Powered 2 Wire programmable transmitter.
RTD or Ohm input
High measurement accuracy
3-wire connection
Programmable sensor error value
1- or 2-channel version -

PR-6334A
TC 2-wire programmable transmitter
Loop Powered 2 Wire programmable transmitter.
TC input
High measurement accuracy
Galvanic isolation
Programmable sensor error value
1- or 2-channel version -

PR-6335A
Universal 2-wire HART transmitter
Universal 2-wire HART programmable transmitter
RTD, TC, Ohm, or mV input
Extremely high measurement accuracy
HART 5 protocol
Galvanic isolation
1- or 2-channel version -

PR-6335D
IECEx Universal 2-wire HART transmitter
Universal IECEx 2-wire HART programmable transmitter
RTD, TC, Ohm, or mV input
Extremely high measurement accuracy
HART 5 protocol
Galvanic isolation
1- or 2-channel version -

PR-6437A
Single or true dual inputs 2-wire HART 7 temperature transmitter
2-wire HART 7 temperature transmitter
RTD, TC, potentiometer, linear resistance and bipolar mV input
Single or true dual inputs with sensor redundancy and drift detection
Wide ambient operating temperature of -50 to +85°C
Total accuracy from 0.014%
2.5 kVAC galvanic isolation
Full assessment to IEC61508 : 2010 for use in SIL 2/3 applications -

PR-6437D
IECEx Single or true dual inputs 2-wire HART 7 temperature transmitter
IECEx 2-wire HART 7 temperature transmitter
RTD, TC, potentiometer, linear resistance and bipolar mV input
Single or true dual inputs with sensor redundancy and drift detection
Wide ambient operating temperature of -50 to +85°C
Total accuracy from 0.014%
2.5 kVAC galvanic isolation
Full assessment to IEC61508 : 2010 for use in SIL 2/3 applications -

PR-7501
Field mounted HART temperature transmitter
Field mounted HART temperature transmitter.
RTD, TC, Ohm, and bipolar mV input and analog output
High definition local operator interface (LOI) with 3 optical buttons
Selectable red or white backlight
Ex d explosion proof / flame proof in aluminum or 316 stainless steel version
HART 7 functionality with HART 5 compatibility
Signal Conditioning Devices / Transmitters